Evaluation of ultrasound treatment on wine protein stability

dc.contributor.author Osorio B., Mónica S. en, fr, es
dc.contributor.colaborator Cardona, Jorge en, fr, es
dc.contributor.colaborator García, Claudia en, fr, es
dc.contributor.colaborator Celotti, Emilio en, fr, es
dc.contributor.colaborator Bellantuono, Elisabetta en, fr, es
dc.coverage.spatial Zamorano en, fr, es
dc.date.accessioned 2019-11-26T21:41:41Z
dc.date.available 2019-11-26T21:41:41Z
dc.date.issued 2019
dc.description 30 p. en, fr, es
dc.description.abstract Haziness is among the most important factors in a high quality wine. Consumers expect a clear solution, even when this does not interfere with olfactory and gustatory characteristics. Ultrasound at 20kHz produces cavitation, which results in colloidal particles collapsing due to pressure increase in the medium. The objective of this study was to evaluate ultrasound effects on protein behavior and stability. Two white wines were submitted to protein stability analyzes, including thermal stability, cold tannin test, ProtoCheck®, particle size, surface electrical charge (SEC) and protein qualification. Randomized complete block designs with factorial arrangements were applied with two times and three amplitudes (phase I) and a similar arrangement including the effect of bentonite (phase II). Thaumatin-like proteins (responsible for haziness) were observed in both wines. Some combinations of amplitude and time were effective in turbidity reduction. In most cases, 90% amplitude was most effective reducing turbidity, although not always reaching total wine stabilization. Cold tannin test revealed that samples subjected to 60 and 90% amplitude reached stability (26-30 NTUs). SEC analysis showed changes in charge due to ultrasound application, requiring different amounts of cationic polymer to neutralize solutions (phase I). Bentonite addition resulted in a generalized protein stabilization. Bentonite concentration was too high to determine ultrasound effectiveness, except for SEC, where combination of ultrasound and bentonite resulted in decrease of protein reactivity. Further investigations should focus on identifying adequate bentonite concentrations to work in combination with ultrasound, determine ultrasound effect on protein concentration and conduct electrophoresis to identify wine protein structure. en, fr, es
dc.identifier.uri http://hdl.handle.net/11036/6553
dc.language.iso eng en, fr, es
dc.publisher Zamorano: Escuela Agrícola Panamericana, 2019 en, fr, es
dc.rights Copyright, Escuela Agrícola Panamericana, 2019 en, fr, es
dc.rights.accessrights closedAccess en, fr, es
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es en, fr, es
dc.subject Amplitude en, fr, es
dc.subject Cavitation, en, fr, es
dc.subject Colloids en, fr, es
dc.subject Sonication en, fr, es
dc.subject Turbidity en, fr, es
dc.title Evaluation of ultrasound treatment on wine protein stability en, fr, es
dc.type Tesis en, fr, es
Archivos
Paquete de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: